MAINTENANCE PANEL

This Topic is relevant to the following aircraft:



 

1
REFUEL pb
ON :  Refueling is initiated according to the BLOCK FUEL quantity displayed on FMGS MCDU INIT B page.
END lt  :  Comes on when refueling is completed. It flashes if refueling aborts or the high level test fails or imbalance is above 3000 kg after refueling.