| REFUELING CONTROL PANEL |
This Topic is relevant to the whole fleet
|
|
FUEL QUANTITY indicator | ||||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||||
|
HI LVL lts | |
| Come on when the system detects a high fuel level. The corresponding refuel valve closes automatically. |
|
OVERFLOW lt | |
| Comes on amber when the overflow sensor is covered in the associated vent tank. |
|
LOAD INC / DEC preselector sw | |
| Pushing the switch up or down increases or decreases the preselected quantity. |
|
TRANSF VALVE sw | ||||||
|
|
APU EMER pb (guarded) | |
| Pushing this button initiates the APU shutdown sequence. |
|
POWER SUPPLY sw | ||||||
|
|
HI LEVEL TEST sw (guarded) | |
| The fuel quantity, PRESELECTED and ACTUAL displays show all 8's.If there is a failure during the high level test the END light flashes and stays flashing after completion. In addition the affected HI LVL light stays on. While HI LEVEL TEST is in process refueling is stopped. |
|
REFUEL / DEFUEL VALVES selector (guarded in NORM) | |||||||||
|
|
MODE SELECT sw (guarded at OFF) | |||||||||
|