This Topic applies to the Whole Fleet
| CAUTION |
|---|
Do not apply this procedure if a fuel leak is suspected. Refer to FUEL LEAK procedure. |
| -WING X FEED | ON | |
|
|
If the WING X FEED valve is open |
|
On the lighter side : |
| -(ALL) FUEL PUMPS (STBY then NORM) | OFF | |
|
When fuel balanced : |
| -PUMPS (NORM then STBY) | ON | |
| -WING X FEED | AUTO | |
|
|
If the WING X FEED valve is failed closed : |
| -OUTER TK XFR | ON | |
| -BANK ANGLE | 3 DEG WING DOWN ON LIGHTER SIDE | |
| -RUDDER TRIM | USE | |