The New SR MD-11 Cockpit contains

Slide SEVEN of SEVEN 

Looking up at overhead panel (i.e. rear of aircraft and front face of flight-deck bulkhead is in top of screen direction)

 Overhead circuit breaker (CB) panel in cockpit. This is the area where fire damaged wiring was found on the accident MD-11. In the original factory installation, all wires entered the CB panel on the right. Note now the clear separation into two bundles of system wires, one right, the other left. To the immediate left of the elevator control cables,  note also two power feeder-cables, running separately, not placed together as in the factory installation.